Abstract

Background and Aims: This research aims to find the image quality of the computed tomography (CT) imaging technique, in terms of noise as a function of the number of projections. Methods: The X-ray Computed Tomography set is started using the rocker switch and the MeasureCT32 program is allowed to run, all devices at two different projections (20 and 300) are implemented. Results: The results of the experiment made clear that increasing the number of projections effectively reconstructs high-quality images in CT image reconstructions, e.g. when implementing 300 projections. This was also clarified with a lower number of projections giving reduced quality of the image, as shown in 20 projections. Conclusions: As increasing, the number of projections that leads to obtain high-quality images, clearer, and less noisy in CT image reconstructions as shown in 300 projections. Thus, reducing the number of projections results in reducing image quality.

Keywords: Image reconstruction · Number of projections · and X-ray computed tomography

References

  1. 1.Bauhs JA, Vrieze TJ, Primak AN, Bruesewitz MR, McCollough CH. CT dosimetry: comparison of measurement techniques and devices. Radiographics. 2008 Jan-Feb;28(1):245-53. doi: 10.1148/rg.281075024. PMID: 18203941. doi:10.1148/rg.281075024
  2. 2.Xuanhao Z, Lijuan S, Bo W, Bing P. Effect of the number of projections in X-ray CT imaging on image quality and digital volume correlation measurement. Measurement. 2022 May 15;194:111061.
  3. 3.Bunker G. X-ray absorption spectrometers. Encyclopaedia of Spectroscopy and Spectrometry2017;610–6. doi:10.1016/b978-0-12-409547- 2.05066-6. doi:10.1016/b978-0-12-409547-
  4. 4.Kumar N, Nachamai M. Noise removal and filtering techniques used in medical images. Orient. J. Comput. Sci. Technol. 2017 Mar 28;10(1):103-13.
  5. 5.Karatas OH, Toy E. Three-dimensional imaging techniques: A literature review. European journal of dentistry. 2014 Jan;8(01):132-40.
  6. 6.Liu X, Shaw CC. Rejection and redistribution of scattered radiation in Scan Equalization Digital Radiography (SEDR): simulation with spot images. Medical physics. 2007 Jul;34(7):2718-
  7. 7.Potts DG, Newton TH. Technical aspects of computed tomography. St. Louis: Mosby; 1981.
  8. 8.BuiAA,Taira RK, editors. Medical imaging informatics. Springer Science & Business Media; 2009.
  9. 9.Davies ER. Image filtering and morphology. In Computer Vision (Fifth Edition) 2018 (pp. 39-92). Academic Press. 10.Mahesh M. The essential physics of medical imaging. Medical physics. 2013;40(7):077301. 11.RoseS,AndersenMS,SidkyEY,PanX. Noise properties of CT images reconstructedbyuseofconstrainedtotal-variation, data-discrepancy minimization. Medical physics. 2015;42(5):2690-8. 12.Xuanhao Z, Lijuan S, Bo W, Bing P. Effect of the number of projections in X-ray CT imaging on image quality and digital volume correlation measurement. Measurement. 2022 May 15;194:111061 13.Salek MF, Beckingham LE. Effect of X-Ray Computed Tomography Imaging Parameters on Quantification of Petrophysical Properties. Earth and Space Science. 2023 Oct;1THE 0(10):e2023EA003095.

Peer review

Peer reviewed by 2 reviewers, who chose to remain anonymous.

Majmaah Journal of Health Sciences · eISSN 1658-8223 · Majmaah University · open access